HKRMINBSYV6T9GB西疇1094.3-2003西疇電力變壓器西疇第3部分:西疇絕緣水平、絕緣試驗和外絕緣空氣間隙西疇
·西疇GB西疇1094.5-2003西疇電力變壓器西疇第5部分:西疇承受短路的能力西疇
·西疇GB西疇13223-2003西疇火電廠大氣污染物排放標準
·西疇GB西疇156-2003西疇標準電壓西疇
·西疇GB西疇19212.1-2003西疇電力變壓器、電源裝置和類似產品的安全西疇第1部分:西疇通用要求和試驗西疇
·西疇GB/T西疇10760.1-2003西疇離網型風力發電機組用發電機西疇第1部分:西疇技術條件西疇
·西疇GB/T西疇10760.2-2003西疇離網型風力發電機組用發電機西疇第2部分:西疇試驗方法西疇
·西疇GB/T西疇1094.10-2003西疇電力變壓器西疇第10部分:西疇聲級測定西疇
·西疇GB/T西疇12325-2003西疇電能質量西疇供電電壓允許偏差西疇
·西疇GB/T西疇14099.1-2004西疇燃氣輪機采購西疇第1部分:總則與定義西疇
·西疇GB/T西疇14099.2-2004西疇燃氣輪機采購西疇第2部分:標準參考條件與額定值西疇
·西疇GB/T西疇15146.11-2004西疇反應堆外易裂變材料的核臨界安全西疇基于限制和控制慢化劑的核臨界安西疇
·西疇GB/T西疇17625.6-2003西疇電磁兼容西疇限值西疇對額定電流大于16A的設備在低壓供電系統中產生的諧波電西疇
·西疇GB/T西疇17680.10-2003西疇核電廠應急計劃與準備準則西疇核電廠營運單位應急野外輻射監測、取樣與分析準西疇
·西疇GB/T西疇17680.6-2003西疇核電廠應急計劃與準備準則西疇場內應急響應職能與組織機構西疇
·西疇GB/T西疇17680.7-2003西疇核電廠應急計劃與準備準則西疇場內應急設施功能與特性西疇
·西疇GB/T西疇17680.8-2003西疇核電廠應急計劃與準備準則西疇場內應急計劃與執行程序西疇
·西疇GB/T西疇17680.9-2003西疇核電廠應急計劃與準備準則西疇場內應急響應能力的保持西疇
·西疇GB/T西疇18039.3-2003西疇電磁兼容西疇環境西疇公用低壓供電系統低頻傳導騷擾及信號傳輸的兼容水平西疇
·西疇GB/T西疇18039.5-2003西疇電磁兼容西疇環境西疇公用供電系統低頻傳導騷擾及信號傳輸的電磁環境西疇
·西疇GB/T西疇18451.2-2003西疇風力發電機組西疇功率特性試驗西疇
·西疇GB/T西疇19068.1-2003西疇離網型風力發電機組西疇第1部分:西疇技術條件西疇
·西疇GB/T西疇19068.2-2003西疇離網型風力發電機組西疇第2部分:西疇試驗方法西疇
·西疇GB/T西疇19068.3-2003西疇離網型風力發電機組西疇第3部分:西疇風洞試驗方法西疇
·西疇GB/T西疇19069-2003西疇風力發電機組控制器西疇技術條件西疇
·西疇GB/T西疇19070-2003西疇風力發電機組西疇控制器西疇試驗方法西疇
·西疇GB/T西疇19071.1-2003西疇風力發電機組西疇異步發電機西疇第1部分:西疇技術條件西疇
·西疇GB/T西疇19071.2-2003西疇風力發電機組西疇異步發電機西疇第2部分:西疇試驗方法西疇
·西疇GB/T西疇19072-2003西疇風力發電機組塔架西疇
·西疇GB/T西疇19073-2003西疇風力發電機組西疇齒輪箱西疇
·西疇GB/T西疇19115.1-2003西疇離網型戶用風光互補發電系統第1部分:西疇技術條件西疇
·西疇GB/T西疇19115.2-2003西疇離網型戶用風光互補發電系統西疇第2部分:西疇試驗方法西疇
·西疇GB/T西疇19184-2003西疇水斗式水輪機空蝕評定西疇
·西疇GB/T西疇19519-2004西疇標稱電壓高于1000V的交流架空線路用復合絕緣子-定義、試驗方法及西疇
·西疇GB/T西疇19568-2004西疇風力發電機組裝配和安裝規范西疇
·西疇GB/T西疇2694-2003西疇輸電線路鐵塔制造技術條件西疇
·西疇GB/T西疇2893.1-2004西疇圖形符號安全色和安全標志西疇第1部分:工作場所和公共區域中安全標志的西疇
·西疇GB/T西疇2900.33-2004西疇電工術語電力電子技術
·西疇GB/T西疇2900.36-2003西疇電工術語西疇電力牽引西疇
·西疇GB/T西疇2900.49-2004西疇電工術語電力系統保護西疇
·西疇GB/T西疇4585-2004西疇交流系統用高壓絕緣于的人工污穢試驗
·西疇GB/T西疇7267-2003西疇電力系統二次回路控制、保護屏及柜基本尺寸系列西疇
·西疇GB/T西疇8564-2003西疇水輪發電機組安裝技術規范西疇
·西疇GB/T西疇8732-2004西疇汽輪機葉片用鋼西疇
·西疇JB/T西疇10317-2002西疇單相油浸式配電變壓器技術參數和要求現向國內銷售西疇S11變壓器
6OCN1HY7KHFKC
電(dian)(dian)(dian)(dian)子(zi)(zi)(zi)變(bian)(bian)壓(ya)器除了體積較小外(wai),在(zai)電(dian)(dian)(dian)(dian)力變(bian)(bian)壓(ya)器與(yu)電(dian)(dian)(dian)(dian)子(zi)(zi)(zi)變(bian)(bian)壓(ya)器二者之間,并(bing)沒有(you)明(ming)確(que)的(de)(de)分界線。一(yi)(yi)般提供(gong)50Hz電(dian)(dian)(dian)(dian)力網絡之電(dian)(dian)(dian)(dian)源均(jun)非常龐(pang)大,它(ta)可能是(shi)涵(han)蓋(gai)有(you)半個(ge)洲地區(qu)那般大的(de)(de)容量。電(dian)(dian)(dian)(dian)子(zi)(zi)(zi)裝(zhuang)置的(de)(de)電(dian)(dian)(dian)(dian)力限制,通常受限于(yu)整流、放大,與(yu)系統其(qi)它(ta)組件(jian)的(de)(de)能力,其(qi)中(zhong)(zhong)有(you)些部(bu)(bu)分屬(shu)(shu)放大電(dian)(dian)(dian)(dian)力者,但(dan)(dan)如(ru)與(yu)電(dian)(dian)(dian)(dian)力系統發電(dian)(dian)(dian)(dian)能力相比較,它(ta)仍然歸屬(shu)(shu)于(yu)小電(dian)(dian)(dian)(dian)力之范圍。各(ge)種(zhong)電(dian)(dian)(dian)(dian)子(zi)(zi)(zi)裝(zhuang)備常用到變(bian)(bian)壓(ya)器,理由是(shi):提供(gong)各(ge)種(zhong)電(dian)(dian)(dian)(dian)壓(ya)階層(ceng)確(que)保系統正常操(cao)作;提供(gong)系統中(zhong)(zhong)以不同電(dian)(dian)(dian)(dian)位操(cao)作部(bu)(bu)分得以電(dian)(dian)(dian)(dian)氣(qi)隔(ge)離;對交流電(dian)(dian)(dian)(dian)流提供(gong)高阻抗,但(dan)(dan)對直流則提供(gong)低的(de)(de)阻抗;在(zai)不同的(de)(de)電(dian)(dian)(dian)(dian)位下(xia),維持(chi)或修(xiu)飾(shi)波形與(yu)頻(pin)率響(xiang)應。「阻抗」其(qi)中(zhong)(zhong)之一(yi)(yi)項重要概念,亦(yi)即電(dian)(dian)(dian)(dian)子(zi)(zi)(zi)學特性之一(yi)(yi),其(qi)乃預設一(yi)(yi)種(zhong)設備,即當(dang)電(dian)(dian)(dian)(dian)路組件(jian)阻抗系從一(yi)(yi)階層(ceng)改(gai)變(bian)(bian)到另外(wai)的(de)(de)一(yi)(yi)個(ge)階層(ceng)時,其(qi)間即使用到一(yi)(yi)種(zhong)設備-變(bian)(bian)壓(ya)器。
現向全國供貨西疇S11變壓器
HAO7WPKIE6西疇6A
1)西疇有大量一級或二級負荷時,宜裝設二臺及以上變壓器,當其中任一臺變壓器斷開時,其余變壓器的容量能滿足一級及二級負荷的用電。一、二級負荷盡可能集中,不宜太分散。
2)西疇季節性負荷容量較大時,宜裝設專用變壓器。如大型民用S4270D27-29西疇27西疇2005.7.29,3:24西疇AM建筑中的空調冷凍機負荷、采暖用電熱負荷等。
3)西疇集中負荷較大時,宜裝設專用變壓器。如大型加熱設備、大型X西疇光機、電弧煉爐等。
4)西疇當照明負荷較大或動力和照明采用共用變壓器嚴重影響照明質量及燈泡壽命時,可設照明專用變壓器。一般情況下,動力與照明共用變壓器。
根據使用環境選擇變壓器:
1)西疇在正常介質條件下,可選用油浸式變壓器或干式變壓器,如工礦企業、農業的獨立或附建變電所、小區獨立變電所等。可供選擇的變壓器有S8、S9、S10、SC(B)9、SC(B)10西疇等。
2)西疇在多層或高層主體建筑內,宜選用不燃或難燃型變壓器,如SC(B)9、SC(B)10、SCZ(B)9、SCZ(B)10西疇等。
3)西疇在多塵或有腐蝕性氣體嚴重影響變壓器安全運行的場所,應選封閉型或密封型變壓器,如B西疇S西疇9、S9西疇-西疇、S10-西疇、SH12-M西疇等。
4)西疇不帶可燃性油的高、低配電裝置和非油浸的配電變壓器,可設置在一同房間內,此時變壓器應帶IP2X保護外殼,以策安全。
根據用電負荷選擇變壓器:
1)西疇配電變壓器的容量,應綜合各種用電設備的設施容量,求出計算負荷(一般不計消防負荷),補償后的視在容量是選擇變壓器容量和臺數的依據。一般變壓器的負荷率85%左右。此法較簡便,可作估算容量之用。
2)西疇GB/T17468-1998《電(dian)力(li)(li)變(bian)壓器(qi)選(xuan)用導(dao)則(ze)》中,推(tui)薦配電(dian)變(bian)壓器(qi)的(de)容量選(xuan)擇,應根據GB/T17211-1998《干式電(dian)力(li)(li)變(bian)壓器(qi)負載(zai)導(dao)則(ze)》及(ji)計算(suan)負荷來(lai)確定其容量。上(shang)述(shu)二導(dao)則(ze)提供了計算(suan)機程序和正常周期負載(zai)圖(tu)來(lai)確定配電(dian)變(bian)壓器(qi)容量。詳見GB/T15164-94西疇及(ji)GB/T17211-1998西疇有關(guan)內容
最優最全的西疇S11變壓器
|